Column Load Calculator
Column Load Calculator calculates a reinforced concrete column's nominal (pure) axial load capacity from its section, concrete strength, reinforcement ratio and steel yield strength, using P0 = 0.85·f'c·(Ag-Ast) + fy·Ast. It's a first-pass check that excludes slenderness, eccentricity and the code's φ strength-reduction factor.
This is the pure (nominal) axial capacity, computed without the φ strength-reduction factor, slenderness or eccentricity effects, not a design capacity.
How it works
- 1Enter the column width and depth in millimeters.
- 2Enter the concrete strength f'c and reinforcement ratio (%).
- 3Enter the steel yield strength fy (commonly 420 MPa).
- 4Read the nominal axial capacity in kN; remember this isn't a design capacity.
Frequently asked questions
Can this result be used directly in design?−+
No. The result is the pure axial capacity, computed without the φ strength-reduction factor (typically ~0.65-0.8), slenderness effects, or eccentricity/moment interaction, actual design capacity is always lower than this.
Can I use this for circular columns?−+
No, the formula only works for rectangular/square sections assuming Ag = width×depth; a circular column needs a separate calculation with Ag = π×D²/4.
How do I choose the reinforcement ratio?−+
Typical reinforced concrete columns use a ratio between 1% and 4% (some codes allow up to 1%-8%); the actual ratio is determined in the structural design.
What units should f'c and fy be entered in?−+
Both should be entered in MPa (N/mm²); the result is automatically converted to kN.
Is the data I enter stored anywhere?−+
No, the entire computation runs in your browser.