The 14 tools in the Electrical Engineering category range from a principle as fundamental as Ohm's Law to three-phase power systems. The most instructive part of this guide is showing that series/parallel resistance and series/parallel capacitance behave as exact opposites, the same words "series/parallel" map to opposite mathematical rules for two different components.
Table of contents
- Ohm's Law and resistor color codes: a circuit's two basic languages
- Series/parallel resistance and capacitance: two opposite rules
- Wire gauge and voltage drop: a preliminary estimate, not a code table
- LED series resistor and transformer turns ratio: two classic circuit calculations
- Power and energy: three-phase, kWh, and dBm
- Frequency, period, and RC time constant: two more tools tied to time
Ohm's Law and resistor color codes: a circuit's two basic languages
Ohm's Law Calculator is a flexible solver: give it any two of the three variables in `V=I×R` (voltage, current, resistance) and it finds the third, working regardless of which two are provided ("I know voltage and resistance, find current" or "I know current and voltage, find resistance"), not a one-direction calculator.
Resistor Color Code Decoder solves a different problem: reading the colored bands on a physical resistor (standard 4-band: two digits + multiplier + tolerance) and converting them to an ohm value. This is a genuinely practical need since resistors don't have numbers printed on them, knowing that multiplier colors like gold (×0.1) and silver (×0.01) sit on a different scale from the other ten colors (black through white, digit values 0-9) is the key to reading a band correctly.
Series/parallel resistance and capacitance: two opposite rules
In Series / Parallel Resistor Calculator, the rule is intuitive: series resistors add directly (`R = R1+R2+...`), parallel resistors combine as the reciprocal of the sum of reciprocals (`1/R = 1/R1+1/R2+...`), adding a parallel resistor always lowers total resistance. In Series / Parallel Capacitor Calculator, the rule flips exactly: parallel capacitors add directly, series capacitors combine as the reciprocal of the sum of reciprocals.
This inverse relationship isn't arbitrary, it's physically consistent: a resistor opposes flow (adding one in series increases total opposition, so direct addition makes sense), a capacitor stores charge (adding one in parallel increases total surface/capacity, so direct addition makes sense there instead), since "series" and "parallel" correspond to a different physical effect for each component, the formulas swap accordingly. Keeping these two tools separate exists specifically to prevent this common mix-up, one that almost every circuits student trips over at least once.
Wire gauge and voltage drop: a preliminary estimate, not a code table
Wire Gauge Estimator divides current by a current-density value (default 5 A/mm²) and rounds the result up to the nearest standard IEC cross-section (from 0.5 mm² to 240 mm²). The code's own comment states its limit plainly: this is a rough sizing, not a substitute for NEC or IEC ampacity tables (the official tables accounting for dozens of factors like cable type, installation method, ambient temperature, grouping), the cross-section actually used in a real installation should come from the relevant code's table.
Voltage Drop Calculator finds a cable's resistance (resistivity × length / cross-section) and computes the voltage drop using a round-trip factor for single-phase (×2) or √3 for three-phase, used to estimate how much voltage is lost from the source over a long cable run (say, garden lighting or a distant motor feed). Together, the two tools give separate preliminary answers to "can it carry the current" and "is the voltage loss acceptable."
LED series resistor and transformer turns ratio: two classic circuit calculations
LED Series Resistor Calculator solves the standard question that has to be asked before lighting an LED: supply voltage is always higher than the LED's forward voltage, and using that difference plus the desired current (`R = (Vsupply − Vled) / Iled`), it finds the required series resistor. Without that resistor, connecting an LED directly to a power source lets it draw unlimited current (and burn out within seconds), this calculation isn't decorative, it's genuinely protective.
Transformer Turns Ratio Calculator works under an ideal-transformer assumption (`Vp/Vs = Np/Ns`, power conserved), a real transformer has iron/copper losses, so actual output is always a bit lower than the ideal value, but the ideal formula is the right starting point for estimating a turns ratio or expected output voltage. The power-conservation assumption also shows that output current changes inversely with the turns ratio, if voltage drops, current rises.
Power and energy: three-phase, kWh, and dBm
Three-Phase Power Calculator computes apparent power (`S=√3×V×I`), real power (`P=S×cosφ`), and reactive power (`Q=S×sinφ`) for a balanced three-phase system, the power factor (cosφ) is the key variable here, because at the same current and voltage, a lower power factor means less real (usable) power for the same apparent power. Energy Use (kWh) Calculator adds a different dimension, time: multiplying a device's power (W) by its runtime (hours) to find total energy consumption, then optionally multiplying by a unit price to show cost, this is literally the calculation behind an electricity bill.
dBm ↔ Watt Converter converts a logarithmic unit common in telecommunications and RF engineering (dBm) into linear watts. The logarithmic scale is chosen for a practical reason: signal power varies across an enormous range (microwatts to watts), and logarithmic representation compresses that wide range into smaller, easier-to-compare numbers, a 10 dBm difference always means a 10x power difference, a ratio that would need recalculating every time in linear watts.
Frequency, period, and RC time constant: two more tools tied to time
Frequency ↔ Period Converter applies the fact that the two values are mathematical reciprocals of each other (`T = 1/f`), knowing how many times a signal repeats per second (Hz) automatically gives how long one repetition takes (seconds), the same information stated two different ways.
RC Time Constant Calculator finds τ (tau), how fast a resistor-capacitor circuit charges or discharges (`τ = R×C`), and adds the practical rule of thumb for "fully charged" (`5τ`, the point at which a capacitor is ~99.3% charged). This value is used to estimate the response time of a timing circuit (say, an LED's blink rate) or a filter circuit, the "5 time constants" rule is the standard way of saying "practically done" in circuit theory.